Sound Level Meter – 831C | Larson Davis

Product code:831C
Supplier:Larson Davis
Price: Inquiry
Description
Specifications
Application
Download

The SoundAdvisor Sound Level Meter Model 831C is designed to make noise measurement easy. Due to its color display, connectivity, extensive software features and small form factor the SoundAdvisor is an ideal choice for handheld operation.

 

Attended measurements are simplified, with the ability to control and monitor data via any PC or mobile device with a standard web interface. Designed with the acoustic professional in mind, the SoundAdvisor offers an elegant solution for complex needs in an easy to use system.


STANDARDS MET BY MODEL 831C

The Model 831C meets the specifications of the following standards:

Sound Level Meter Standards

IEC61672-1 Ed. 2.0 (2013) Class 1, Group X
IEC60651 Ed 1.2 (2001) plus Amendment 1 (1993-02) and Amendment 2 (2000-10) Type 1, Group X
IEC60804 (2000-10) Type 1, Group X
ANSI S1.4-2014 Class 1
ANSI S1.43-1997 Type 1
DIN 45657
Octave Filter Standards (Option 831C- OB3)
IEC61260 Ed. 2.0 (2014) Class 1, all filters
ANSI S1.11-2014 Class 1, all filters

Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use

2006/95/EC Low Voltage Safety Directive
IEC 61010-1 Ed. 3.0 (2010-06)
EMC Immunity and Emission
2004/08/EC EMC Directive
IEC 61326-1 Ed. 2.0 (2012-07)
IEC 61672-1 Ed. 2.0 (2013-09)
FCC Title 47 CRF Part 15, Class B

 

 


Specifications


General

Reference Level 114.0 dB re. 20 µPa
Reference Level Range Single large range for SLM measurements
Reference Frequency 1.000 Hz
Reference Direction 0° is perpendicular to the microphone diaphragm
Operating Temperature ≤ ± 0.5 dB error between -22°F to +122 °F (-30 °C to 60 °C)
Storage temperature -22 °F đến 158 °F (-30 °C đến 60 °C)
Humidity ≤ ± 0.5 dB error from 10% to 99% relative humidity (non-condensing)
Equivalent Microphone Capacitance 12 pF
Digital Display Update Rate Four times per second (0.25 sec between updates). First display indication is available 0.25 seconds after initiation of a measurement. Chỉ báo hiển thị đầu tiên có sẵn sau 0,25 giây sau khi bắt đầu đo.
Effect of an Extension Cable None up to 200 ft (61 m) with EXCxxx cable
Approvals CE, ROHS, WEEE
Extended Weather Options -40 °F to +158 ºF (-40 °C to +70 ºC) operation with CER-831-E

Physical

Length with Microphone and Preamplifier 11.35 in 29.0 cm
Length, Instrument Body Only 8.8 in 22.4 cm
Width 2.8 in 7.1 cm
Depth 1.6 in 4.1 cm
Weight with Batteries, No Preamplifer or Microphone 17.3 oz 490 g
Weight with Batteries, Preamplifer, and Microphone 18.8 oz 532 g

Sound Level Meter Specifications

Averaging (Integration Method) Linear or Exponential
Time Weightings Slow, Fast,or Impulse
Frequency Weightings A, C, and Z
Peak Detector Frequency Weighting A, C, or Z
Gain 0 dB or +20 dB
Sample Rate 51,200 Hz
Peak Rise Time 30 µs
Metrics Measured Leq, Lmax, Lmin, Lpeak, Ln (6 values), LDN, LDEN, LCeq – LAeq

Resolution Specifications

Levels 0.1 dB
Elapsed Time 0.1 s
Real-time Clock 1 s
Calendar Through January 1, 2038

Integration Time

Time Averaged Levels and Sound Exposure Levels
Minimum 0.1 s
Maximum with Daily Autostore Enabled Unlimited
Maximum with Daily Autostore Disabled > 23 days with error < 0.5 dB

Broadband Noise Levels

Self-generated Electrical Noise 0 dB Gain 20 dB Gain
Frequency Weightings Typical (dB) Max (dB) Typical (dB) Max (dB)
A 13 15 6 10
C 15 22 12 16
Z 22 25 19 26
Self-generated Total Noise 0 dB Gain 20 dB Gain
Weighting Typical (dB) Max (dB) Typical (dB) Max (dB)
A 18 19 17 17
C 18 23 17 19
Z 23 26 21 26
Note: Combination of the electronic noise and the thermal noise of the 377B02 microphone at 68 °F (20 °C) measured in a sealed and vibration isolated cavity with an averaging time of 60 seconds. Electronic noise of the instrument with an ADP090 (12 pF) in place of the microphone highest anticipated self-generated noise.

 

 


FEATURES


Ln Statistics

Number of Selectable Parameters 6 in xx.xx% format
Resolution 0.1 dB
Spectral Statistics Requires Octave Analysis option (831C-OB3)
Markers
Number of Markers 10
Prenamed Markers Truck, Automobile, Motorcycle, Aircraft, Exclude
Back Erase Time 5 or 10 s

Measurement Control Modes

Available Modes Manual Stop, Timed Stop, Stop when Stable, Continuous, Single Block Timer, Daily Block Timer
Timed Stop Time in hh:mm:ss
Stop When Stable Delta level in xx.x dB and time in hh:mm:ss
Continuous with Daily Auto-Store 1, 2, 4, 6, 12, 24, 48, 96 or 144 files per day, automated file numbering
“yymmddnn.LD0”
Restart after Power Failure Automatic if powered by 12 VDC and continuous run mode
Single Block Timer Start date and time to end date and time
Daily Block Timer Up to 3 blocks between each start and end date

Clock Stability

<1 sec in 24 hours, at 75 ºF (+24 ºC)
<10 sec in 30 days, at -40 °F to +158 °F (-40 °C to +70 °C)
<1 s when using NTP
Microphone Input
Connector Latching 5-pin connector
Input Impedance 100 kΩ and 300 pF
Full Scale Input (0 dB gain) 14 Vpeak
ICP Current (requires ADP074) 4 mA

AC/DC Output

Jack 2.5 mm (3/32 in) female
AC Output Voltage Range ± 14 Vpeak (preamplifier output)
± 2.1 Vpeak with 0, 20 or 40 dB gain (for LINE inputs)
AC Output Recommended Load 10 kΩ or greater
DC Output Voltage Scale 10 mV per dB, 0 V for 0 dB, 1 V = 100 dB
DC Output Frequency & Time Weighting Follows SLM Settings: A, C, or Z and S, F, or I

Power

Storage battery type 4-AA (LR6) NiMH, 1.5 V Lithium or Alkaline cells (supplied with 2500 mAh NiMH)
External Power (5 V from USB) USB Mini-B connector to * USB interface from computer * PSA029 AC to DC power adaptor
External Power I/O connector: 10 to 25 VDC (Use cable CBL140)
Operating Time (with power save options) > 18 hours (1.5 V Lithium batteries)
> 8 hours (Alkaline or NiMH batteries)
Power Consumption with PRM831 1.1 W (backlight off, running)
≤ 2 W (with DVX012)
5 W (maximum)

Memory Retention

Data Memory Non-volatile flash memory, backup performed every minute
Real-time Clock ≥ 1 year with batteries removed
  • Environmental noise assessment
  • Noise reduction validation
  • Product quality control
  • Spectral noise analysis

Related Products

product thumbnail

IEPE Measurement DAQ HAT for Raspberry Pi® MCC 172

The MCC 172 is a two channel DAQ HAT for making sound and vibration measurements from IEPE sensors like accelerometers and microphones.

product thumbnail

The DT9847 Series of USB dynamic signal analyzers

The DT9847 Series are high-accuracy, dynamic signal acquisition modules designed for sound and vibration applications

product thumbnail

Internet Enabled Vibration/Acoustic Logger WebDAQ 504

The WebDAQ 504 is a stand-alone, vibration and acoustic data logger designed for remote monitoring, analysis, and control.

product thumbnail

The DT9857E USB dynamic signal analyzer

The DT9857E is a high accuracy dynamic signal acquisition module for noise, vibration, and acoustic measurements.

product thumbnail

The DT9837 Series of USB dynamic signal analyzers

The DT9837 Series of USB dynamic signal analyzers provide highly accurate measurements for portable sound, vibration, and force response measurements.

product thumbnail

Human Vibration Meter – HVM200

The HVM200 is a small rugged vibration meter with built in Wi-Fi that can be used to measure hand-arm, whole body and general vibration. It includes the metrics and frequency weightings needed to measure human vibration. This 3 channel meter meets the requirements of ISO 8041:2005 and it is designed to measure per ISO 2631-1, 2 & 5 and ISO 5349 in support of the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Values (TLVs) and the directive 2002/44/EC.

product thumbnail

Sound Level Meter – 831C | Larson Davis

The SoundAdvisor Sound Level Meter Model 831C is designed to make noise measurement easy. Due to its color display, connectivity, extensive software features and small form factor the SoundAdvisor is an ideal choice for handheld operation.

Unsolicited failed error
Please resend information

You have successfully submitted