equipment slide 0
equipment slide 0

Promo 3000

Product code:Promo 3000
Supplier:Palas
Price: Inquiry
Description
Specifications
Application
Download

Scattered-light aerosol spectrometer system for process measurement technology and monitoring applications with two sensors for quasi simultaneously measurements

Aerosol Spectrometers Promo 3000

  • Measuring range of 0.2 to 100 µm (4 measuring ranges selectable in one device)
  • Up to four measuring ranges in only one device: 0,2 µm – 10 µm; 0,3 µm – 17 µm; 0,6 µm – 40 µm; 2 µm – 100 µm (additionally for sensors 2300 and 2500)
  • Up to 128 size channels per measuring range
  • Concentration range of 1 particle/cm3 up to 10^6 particles/cm3
  • Very high and reproducible counting efficiency rate starting at 0.2 µm
  • Optical fibre technology
  • Simple operation with a large touch display
  • Calibration, cleaning and lamp replacement can all be performed independently by the customer
  • External control by RS 232 or Ethernet
  • PDAnalyze analysis software
  • Optional: Software PDControl for operation as welas® digital available
  • Low maintainance costs with Aerosol Spectrometers Promo 3000
  • Reliable function

*Learn more about Palas: Here

*Fanpage: DIGI TECHNOLOGIES


Technical Data

Description
Interfaces USB, Ethernet (LAN), RS232/485, Wi-Fi
Measurement range (size) Up to 128 (64/decade)
Measuring principle Optical light-scattering
Measurement range (number CN) < 1 • 10^6 particles/cm3
Time resolution up to 1 s
Thermodynamic conditions 10 – 40 °C

-100 – 50 mbar

Volume flow 5 l/min
Data acquisition Digital, 20 MHz processor, 256 raw data channels
Light Source Xenon arc lamp 35 W
Power consumption 100W
User interface Touchscreen, 800 • 480 pixel, 7" (17.78 cm)
Power supply 115 – 230 V; 50 – 60 Hz
Housing Table housing, optionally with mounting brackets for rack-mounting
Dimensions 185 x 450 x 315 mm (H x W x D) (19″)
Support options Direct remote access, Palas® webserver service
Weight Approx. 8 kg (control unit), approx. 2.8 kg (per sensor)
Operating system Windows embedded
Data logger storage 4 GB
Software PDControl, FTControl, PDAnalyze
Installation conditions +5 – +40 °C (control unit)
Measurement range (size) 0.2 – 10 µm,

0.3 – 17 µm,

0.6 – 40 µm,

2 – 100 µm

  • Emission monitoring of installations
  • Control of grinding and classification processes
  • Monitoring of production processes in the food, pharmaceuticals and chemicals industries
  • Testing of complete filters, inertial and wet separators or electrostatic precipitators

Variations:

  • Promo® 3000 H With heating regulation up to 250 °C for welas® aerosol sensors
  • Promo® 3000 HP With automatic regulation of sampling volume flow by the aerosol sensors welas® under overpressure up to 10 bar or in temperatures to 120 °C

Related Products

product thumbnail

Dilution system – PMPD 1000

Dilution system ejector for the PMP application with dilution factor 1:1000. The PMPD 1000 dilution system is a dilution system according to the ejector principle that was especially developed for the PMP application or the PMP measurement chain. The PMPD 1000 achieves a dilution factor of 1:1000 by means of a thermodiluter up to 200°C.

product thumbnail

Dilution system – PMPD 100

Dilution system ejector for the PMP application with dilution factor 1:100 The PMPD 100 dilution system is a dilution system according to the ejector principle that was especially developed for the PMP application or the PMP measurement chain. The PMPD 100 achieves a dilution factor of 1:000 by means of a thermodiluter up to 200°C.

product thumbnail

Dilution systems – DC 10000

The DC 10000 consists of four cascaded special dilution systems with the dilution factor 1:10. The DC 10000 dilution cascade has one aerosol inlet and four aerosol outlets. Depending on which aerosol outlet is connected to the measuring device, the aerosol with the dilution factors 1:10, 1:100, 1:1,000 or 1:10,000 are diluted and measured.

product thumbnail

Dilution system – KHG 10

KHG 10 D dilution system heatable and pressure-resistant up to 10 bar for isothermal and isobaric dilution with a dilution factor of 1:10.

product thumbnail

Dilution system – VKL 100

Dilution system with dilution factor 1:100 The Palas® VKL 100 dilution systems are used in vertical operation for the particle size range up to 2 µm for applications in the clean room. Dilution factors of up to 1:100,000 are achieved by cascading several VKL systems.

product thumbnail

Dilution system – VKL 10

The VKL 10 series of dilution systems can reduce the concentration of aerosols by the dilution factor 01:10, also of very highly concentrated aerosols, in a defined and reliable way. The Palas® VKL 10 dilution systems are used in vertical operation for the particle size range up to 20 µm for powders and dusts. Dilution factors of up to 1:100,000 are achieved by cascading several VKL systems.

product thumbnail

Dilution system – LDD 100

The dilution of large droplets is particularly important when measuring highly concentrated droplet aerosols. Since large droplets are difficult to dilute, standard systems only work up to a size of 1 – 2 μm. The newly developed dilution system LDD 10 (dilution factor 10) is the first system to dilute almost loss-free large droplets up to 10 μm.

product thumbnail

Dilution system LDD 10

The dilution of large droplets is particularly important when measuring highly concentrated droplet aerosols. Since large droplets are difficult to dilute, standard systems only work up to a size of 1 – 2 μm. The newly developed dilution system LDD 10 (dilution factor 10) is the first system to dilute almost loss-free large droplets up to 10 μm.

product thumbnail

LSPG 16890 system

Aerosol generator for KCl and other salt particles up to 10 μm based on ISO 16890

product thumbnail

AGK 2000

Generation of solid particles out of suspensions, solutions and biological agents Solid particle aerosols produced from suspensions, e.g. with biological agents, and solutions such as NaCl and KCl, are required for numerous applications in research, development and quality assurance.

product thumbnail

DNP Digital 3000

Generation of nano-scale test aerosols from graphite, silver (Ag), gold (Au), copper (Cu), etc. through condensation; Carrier gas: Nitrogen or Argon (Replacement product of the GFG 1000)

product thumbnail

BEG 3000

Test aerosols from powder, dust, pollen, etc.; mass flow approx. 8 g/h – 7.3 kg/h; with automatic mass flow monitoring and refill unit

Unsolicited failed error
Please resend information

You have successfully submitted