Test aerosols from powder, dust, pollen, etc.; mass flow approx. 8 g/h – 7.3 kg/h; with automatic mass flow monitoring and refill unit

 

  • Excellent short-term and long-term dosing constancy
  • Easy to operate
  • Quick and easy to clean
  • Remote control or computer-controlled
  • Pulse mode
  • Easy to fill while in operation
  • Large reservoir (1500 cm3)
  • Automatic mass flow control with the BEG 2000
  • Long dosing time over several days with the BEG 3000
  • Robust design, proven in industrial applications
  • Reliable function
  • Reduces your operating expenses
  • Low maintenance

Technical Data

Values
Volume flow 5 – 10 m3/h
Power supply 115 – 230 V, 50 – 60 Hz
Particle material Non-cohesive powders and bulks
Dosing time Several hours nonstop
Maximum particle number concentration Ca. 107 particles/cm3
Mass flow (particles) Type A: 8 g – 550 g/h (with reference to SAE Fine, A2 dust)

Type B: 100 – 6,000 g/h (with reference to SAE Fine, A2 dust)

Type C: 350 – 7,300 g/h (with reference to SAE Fine, A2 dust)

Carrier/dispersion gas Random (generally air)
Pre-pressure 4 – 8 bar
Compressed air connection Quick coupling
Aerosol outlet connection Loại A: Ø inside = 6,4 mm; Ø outside = 10 mm;

Loại B: Ø inside = 8 mm; Ø outside = 12 mm;

Loại C: Ø inside = 8 mm, Ø outside = 12 mm

Reservoir volume 1,500 cm3
Filling quantity 15 kg
Particle size range 0.1 – 200 µm
  • Filter industry: Loading test of: engine filters as per ISO 5011, Hot gas filters, Bag filters, Air filters, Cyclones; Engine crash tests
  • Chemical and pharmaceutical industry
  • Cement industry

 

Variations:

 

  • BEG 3000 A: Powder disperser with weighing unit for low mass flows of approx. 8 g/h – 550 g/h; mass flow monitoring and control with automatic refill unit
  • BEG 3000 B: Powder disperser with weighing unit for low mass flows of approx. 100 g/h – 6 kg/h; mass flow monitoring and control with automatic refill unit

Related Products

product thumbnail

Dilution system – PMPD 1000

Dilution system ejector for the PMP application with dilution factor 1:1000. The PMPD 1000 dilution system is a dilution system according to the ejector principle that was especially developed for the PMP application or the PMP measurement chain. The PMPD 1000 achieves a dilution factor of 1:1000 by means of a thermodiluter up to 200°C.

product thumbnail

Dilution system – PMPD 100

Dilution system ejector for the PMP application with dilution factor 1:100 The PMPD 100 dilution system is a dilution system according to the ejector principle that was especially developed for the PMP application or the PMP measurement chain. The PMPD 100 achieves a dilution factor of 1:000 by means of a thermodiluter up to 200°C.

product thumbnail

Dilution systems – DC 10000

The DC 10000 consists of four cascaded special dilution systems with the dilution factor 1:10. The DC 10000 dilution cascade has one aerosol inlet and four aerosol outlets. Depending on which aerosol outlet is connected to the measuring device, the aerosol with the dilution factors 1:10, 1:100, 1:1,000 or 1:10,000 are diluted and measured.

product thumbnail

Dilution system – KHG 10

KHG 10 D dilution system heatable and pressure-resistant up to 10 bar for isothermal and isobaric dilution with a dilution factor of 1:10.

product thumbnail

Dilution system – VKL 100

Dilution system with dilution factor 1:100 The Palas® VKL 100 dilution systems are used in vertical operation for the particle size range up to 2 µm for applications in the clean room. Dilution factors of up to 1:100,000 are achieved by cascading several VKL systems.

product thumbnail

Dilution system – VKL 10

The VKL 10 series of dilution systems can reduce the concentration of aerosols by the dilution factor 01:10, also of very highly concentrated aerosols, in a defined and reliable way. The Palas® VKL 10 dilution systems are used in vertical operation for the particle size range up to 20 µm for powders and dusts. Dilution factors of up to 1:100,000 are achieved by cascading several VKL systems.

product thumbnail

Dilution system – LDD 100

The dilution of large droplets is particularly important when measuring highly concentrated droplet aerosols. Since large droplets are difficult to dilute, standard systems only work up to a size of 1 – 2 μm. The newly developed dilution system LDD 10 (dilution factor 10) is the first system to dilute almost loss-free large droplets up to 10 μm.

product thumbnail

Dilution system LDD 10

The dilution of large droplets is particularly important when measuring highly concentrated droplet aerosols. Since large droplets are difficult to dilute, standard systems only work up to a size of 1 – 2 μm. The newly developed dilution system LDD 10 (dilution factor 10) is the first system to dilute almost loss-free large droplets up to 10 μm.

product thumbnail

LSPG 16890 system

Aerosol generator for KCl and other salt particles up to 10 μm based on ISO 16890

product thumbnail

AGK 2000

Generation of solid particles out of suspensions, solutions and biological agents Solid particle aerosols produced from suspensions, e.g. with biological agents, and solutions such as NaCl and KCl, are required for numerous applications in research, development and quality assurance.

product thumbnail

DNP Digital 3000

Generation of nano-scale test aerosols from graphite, silver (Ag), gold (Au), copper (Cu), etc. through condensation; Carrier gas: Nitrogen or Argon (Replacement product of the GFG 1000)

product thumbnail

BEG 3000

Test aerosols from powder, dust, pollen, etc.; mass flow approx. 8 g/h – 7.3 kg/h; with automatic mass flow monitoring and refill unit