equipment slide 0
equipment slide 0

Mask / respirator inspection system – Mas-Q-Check

Product code:Mas Q Check
Supplier:Palas
Price: Inquiry
Description
Specifications
Application
Download

The Mas-Q-Check was developed by Palas to subject protective masks to a quick, simple and yet meaningful test before use. A particle counting measurement device is used, which is able to detect efficiencies in the size range of viruses and bacteria. The system can also be used for training purposes as it immediately shows the efficiency of protective masks.

Mas-Q-Check mask inspection system with:

  • Self-explanatory operation
  • Quick easy and exact measurement of the degree of protection of masks on site
  • Quality control of masks in daily use
  • Reral evaluation of the degree of protection from filtration efficiency and leakage combined.
  • Highly resolved measurement result in the range of 140 nm up to 1 µm
  • Fully automated test
  • Evaluation of the degree of protection in comparison to the FFP class, optional display with regard to particle size
  • Clear distinction of protection degree in the size range of viruses and bacteria and above

*Learn more about Palas: Here

*Fanpage: DIGI TECHNOLOGIES


Technical Data

Description
Measurement range (size) 0.14 – 10 µm
Measuring principle Optical light-scattering
Measurement range (number CN) 0 – 20,000 particles/cm³
Data acquisition Digital, 20 MHz processor, 256 raw data channels
Power consumption Approx. 200 W
User interface Touchscreen, 800 • 480 pixel, 7" (17.78 cm)
Reported data Protection class filter mask
Volume flow (clean air) 9.5 l/min, 95 l/min
  • Confirmation of the degree of protection of masks
  • Confirmation of the protection of employees working in medical environment
  • Training to show the correct use of masks with direct measurement of the degree of protection
  • Evaluation of the real degree of protection in comparison of the FFP Class

Related Products

product thumbnail

Dilution system – PMPD 1000

Dilution system ejector for the PMP application with dilution factor 1:1000. The PMPD 1000 dilution system is a dilution system according to the ejector principle that was especially developed for the PMP application or the PMP measurement chain. The PMPD 1000 achieves a dilution factor of 1:1000 by means of a thermodiluter up to 200°C.

product thumbnail

Dilution system – PMPD 100

Dilution system ejector for the PMP application with dilution factor 1:100 The PMPD 100 dilution system is a dilution system according to the ejector principle that was especially developed for the PMP application or the PMP measurement chain. The PMPD 100 achieves a dilution factor of 1:000 by means of a thermodiluter up to 200°C.

product thumbnail

Dilution systems – DC 10000

The DC 10000 consists of four cascaded special dilution systems with the dilution factor 1:10. The DC 10000 dilution cascade has one aerosol inlet and four aerosol outlets. Depending on which aerosol outlet is connected to the measuring device, the aerosol with the dilution factors 1:10, 1:100, 1:1,000 or 1:10,000 are diluted and measured.

product thumbnail

Dilution system – KHG 10

KHG 10 D dilution system heatable and pressure-resistant up to 10 bar for isothermal and isobaric dilution with a dilution factor of 1:10.

product thumbnail

Dilution system – VKL 100

Dilution system with dilution factor 1:100 The Palas® VKL 100 dilution systems are used in vertical operation for the particle size range up to 2 µm for applications in the clean room. Dilution factors of up to 1:100,000 are achieved by cascading several VKL systems.

product thumbnail

Dilution system – VKL 10

The VKL 10 series of dilution systems can reduce the concentration of aerosols by the dilution factor 01:10, also of very highly concentrated aerosols, in a defined and reliable way. The Palas® VKL 10 dilution systems are used in vertical operation for the particle size range up to 20 µm for powders and dusts. Dilution factors of up to 1:100,000 are achieved by cascading several VKL systems.

product thumbnail

Dilution system – LDD 100

The dilution of large droplets is particularly important when measuring highly concentrated droplet aerosols. Since large droplets are difficult to dilute, standard systems only work up to a size of 1 – 2 μm. The newly developed dilution system LDD 10 (dilution factor 10) is the first system to dilute almost loss-free large droplets up to 10 μm.

product thumbnail

Dilution system LDD 10

The dilution of large droplets is particularly important when measuring highly concentrated droplet aerosols. Since large droplets are difficult to dilute, standard systems only work up to a size of 1 – 2 μm. The newly developed dilution system LDD 10 (dilution factor 10) is the first system to dilute almost loss-free large droplets up to 10 μm.

product thumbnail

LSPG 16890 system

Aerosol generator for KCl and other salt particles up to 10 μm based on ISO 16890

product thumbnail

AGK 2000

Generation of solid particles out of suspensions, solutions and biological agents Solid particle aerosols produced from suspensions, e.g. with biological agents, and solutions such as NaCl and KCl, are required for numerous applications in research, development and quality assurance.

product thumbnail

DNP Digital 3000

Generation of nano-scale test aerosols from graphite, silver (Ag), gold (Au), copper (Cu), etc. through condensation; Carrier gas: Nitrogen or Argon (Replacement product of the GFG 1000)

product thumbnail

BEG 3000

Test aerosols from powder, dust, pollen, etc.; mass flow approx. 8 g/h – 7.3 kg/h; with automatic mass flow monitoring and refill unit

Unsolicited failed error
Please resend information

You have successfully submitted