PMFT 1000M

Product code:PMFT 1000M
Supplier:Palas
Price: Inquiry
Description
Specifications
Application
Download

The PMFT 1000 M tests face masks better than the standards Test of total penetration better than the standard, exact analysis of filter mask efficiency from 145 nm to 5 µm

PMFT 1000 M for reliable continuous operation in routine monitoring of half masks. Test of total penetration better than the standard, exact analysis of filter mask efficiency from 145 nm to 5 µm Both total photometric penetration and fractional efficiency are tested e.g., the efficiency in the whole size range respectively the particle size-dependent penetration.

In addition, the PMFT 1000 M meets the requirements for respirators specified by the CCF (Covid Certified Filter) quality seal .

The PMFT 1000 M is equipped with aerosol generators for measuring penetration with oil and salt. Measurement procedures for quick quality control (short test) or for testing according to standard (exposure test) are supplied.

Operation and automatic printout of the measurement results are therefore easy even for inexperienced users.

The measurement of total penetration and penetration via particle size is carried out with the high-precision aerosol photometer Promo LED 2300.

The size distribution of the test aerosol according to the standard is as follows:

EN 149

  • Oil: Media diameter 290 nm | Geom. standard deviation 1.85
  • Salt: Media diameter 70 nm | Geom. standard deviation 2.5

42 CFR 84 / GB 2626

  • Oil: Media diameter 200 nm | Geom. standard deviation 1.6
  • Salt: Media diameter 55 nm | Geom. standard deviation 1.86

Based on the measurement of the particle penetration via the particle size, the PMFT can also be used to consider the tolerances in the particle size distribution according to EN 13274-7 as min./max. penetration value. In addition, comparative values to other manufacturers are possible (option).

The comparison with other standards (42CFR84/NIOSH) is also easy with the 42CFR84 upgrade KIT.

Benefits:

  • Test rig working principle better than EN 149 and EN 13274-7
  • Equivalent to GB 2626, 42 CFR 84 and ASTM 2299-3 by additional software option
  • Test of community masks equivalent to CWA 17553
  • Meets the requirements for respirators specified by the CCF (Covid Certified Filter) quality seal
  • Includes two aerosol generators for NaCl and for oil
  • Testing of fractional efficiency, e.g. efficiency in whole size range of 145 nm up to 40 µm
  • Exact analysis of filter and filter mask efficiency for SARS-CoV-2 (size approx. 120 nm up to 160 nm). Efficiency also displayed at 145 nm
  • Future proof: Works with any kind of aerosol without adjustments
  • Further measurement of differential pressure, e.g. as well within different face velocities to simulate test of breathing resistance
  • Face velocity adjustable between 1.5 – 70 cm/s
  • Product capable of fast quality assurance AND continuous optimization in R&D (display of size distribution)
  • Individual face mask adapter for your product
  • Attractive 2 years maintenance package for availability of test rig
  • Can be operated as Mas Q-Check with optional Mas-Q-Head

The software extension additionally offers:

  • Display of penetration results of the entire tolerance range of the size distribution according to EN 13274-7

*Learn more about Palas: Here

*Fanpage: DIGI TECHNOLOGIES


Technical Data

Description
Measurement range (size) 0.145 – 40 µm
Volume flow 1 – 27 m3/h (pressure mode)
Power supply 115-230 V; 50/60 Hz
Dimensions Approx. 600 • 1,800 • 900 mm (W • H • D)
Installation conditions 10 – 40 °C
Test conditions according to standard 19 – 23 °C
Inflow velocity 1,5 to 70 cm/s
Differential pressure measurement 0 – 1,200 Pa
Test area of the medium 100 cm²
Compressed air supply 6 – 8 bar
  • Test of respiratory masks
  • Exact analysis of filter mask efficiency for e.g. Corona Virus
  • Filter testing for HEPA quality
  • Can be operated as Mas Q-Check with optional Mas-Q-Head

Related Products

product thumbnail

Dilution system – PMPD 1000

Dilution system ejector for the PMP application with dilution factor 1:1000. The PMPD 1000 dilution system is a dilution system according to the ejector principle that was especially developed for the PMP application or the PMP measurement chain. The PMPD 1000 achieves a dilution factor of 1:1000 by means of a thermodiluter up to 200°C.

product thumbnail

Dilution system – PMPD 100

Dilution system ejector for the PMP application with dilution factor 1:100 The PMPD 100 dilution system is a dilution system according to the ejector principle that was especially developed for the PMP application or the PMP measurement chain. The PMPD 100 achieves a dilution factor of 1:000 by means of a thermodiluter up to 200°C.

product thumbnail

Dilution systems – DC 10000

The DC 10000 consists of four cascaded special dilution systems with the dilution factor 1:10. The DC 10000 dilution cascade has one aerosol inlet and four aerosol outlets. Depending on which aerosol outlet is connected to the measuring device, the aerosol with the dilution factors 1:10, 1:100, 1:1,000 or 1:10,000 are diluted and measured.

product thumbnail

Dilution system – KHG 10

KHG 10 D dilution system heatable and pressure-resistant up to 10 bar for isothermal and isobaric dilution with a dilution factor of 1:10.

product thumbnail

Dilution system – VKL 100

Dilution system with dilution factor 1:100 The Palas® VKL 100 dilution systems are used in vertical operation for the particle size range up to 2 µm for applications in the clean room. Dilution factors of up to 1:100,000 are achieved by cascading several VKL systems.

product thumbnail

Dilution system – VKL 10

The VKL 10 series of dilution systems can reduce the concentration of aerosols by the dilution factor 01:10, also of very highly concentrated aerosols, in a defined and reliable way. The Palas® VKL 10 dilution systems are used in vertical operation for the particle size range up to 20 µm for powders and dusts. Dilution factors of up to 1:100,000 are achieved by cascading several VKL systems.

product thumbnail

Dilution system – LDD 100

The dilution of large droplets is particularly important when measuring highly concentrated droplet aerosols. Since large droplets are difficult to dilute, standard systems only work up to a size of 1 – 2 μm. The newly developed dilution system LDD 10 (dilution factor 10) is the first system to dilute almost loss-free large droplets up to 10 μm.

product thumbnail

Dilution system LDD 10

The dilution of large droplets is particularly important when measuring highly concentrated droplet aerosols. Since large droplets are difficult to dilute, standard systems only work up to a size of 1 – 2 μm. The newly developed dilution system LDD 10 (dilution factor 10) is the first system to dilute almost loss-free large droplets up to 10 μm.

product thumbnail

LSPG 16890 system

Aerosol generator for KCl and other salt particles up to 10 μm based on ISO 16890

product thumbnail

AGK 2000

Generation of solid particles out of suspensions, solutions and biological agents Solid particle aerosols produced from suspensions, e.g. with biological agents, and solutions such as NaCl and KCl, are required for numerous applications in research, development and quality assurance.

product thumbnail

DNP Digital 3000

Generation of nano-scale test aerosols from graphite, silver (Ag), gold (Au), copper (Cu), etc. through condensation; Carrier gas: Nitrogen or Argon (Replacement product of the GFG 1000)

product thumbnail

BEG 3000

Test aerosols from powder, dust, pollen, etc.; mass flow approx. 8 g/h – 7.3 kg/h; with automatic mass flow monitoring and refill unit

Unsolicited failed error
Please resend information

You have successfully submitted