equipment slide 0
equipment slide 0

NRG T60 temperature sensor

Product code:NRG T60
Supplier:NRG Systems
Price: Inquiry
Description
Specifications
Application
Download

The NRG T60 Temperature Sensor brings a new sensing element to the NRG 110S’s time-tested form. The result is a durable, reliable sensor that offers reduced measurement uncertainty and is capable of capturing measurements at higher temperatures. Because the T60 maintains the same physical design, signal output, and wiring scheme as the 110S, transitioning to this next generation sensor is exceptionally easy.

 

The T60 is ideally suited for the temperature measurement requirements of remote wind and solar energy studies. Recommended uses of the data from this sensor include calculating energy density calculations; monitoring air temperature; calculating atmospheric stability conditions; identifying icing conditions in cold climates; and estimating PV panel efficiency, which is temperature dependent.

 

*Please note: T60C is the calibrated version of this sensor.

 
4.6m cable (#9400)

13m cable (#9411) 67m cable (#9402) 90m cable (#9403) 110m cable (#9404) 13m Cable - Calibrated (#9401)

DESCRIPTION

 
Sensor type Integrated circuit ambient temperature sensor with six plate radiation shield Integrated circuit ambient temperature sensor with six plate radiation shield Integrated circuit ambient temperature sensor with six plate radiation shield Integrated circuit ambient temperature sensor with six plate radiation shield Integrated circuit ambient temperature sensor with six plate radiation shield Integrated circuit ambient temperature sensor with six plate radiation shield
Applications
  • Wind and solar resource assessment
  • Wind and solar plant operations
  • Meteorological studies
  • Environmental monitoring
  • Wind and solar resource assessment
  • Wind and solar plant operations
  • Meteorological studies
  • Environmental monitoring
  • Wind and solar resource assessment
  • Wind and solar plant operations
  • Meteorological studies
  • Environmental monitoring
  • Wind and solar resource assessment
  • Wind and solar plant operations
  • Meteorological studies
  • Environmental monitoring
  • Wind and solar resource assessment
  • Wind and solar plant operations
  • Meteorological studies
  • Environmental monitoring
  • Wind and solar resource assessment
  • Wind and solar plant operations
  • Meteorological studies
  • Environmental monitoring
Sensor range -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F)
Instrument compatibility All NRG loggers All NRG loggers All NRG loggers All NRG loggers All NRG loggers All NRG loggers

OUTPUT SIGNAL

 
Signal type Linear analog voltage Linear analog voltage Linear analog voltage Linear analog voltage Linear analog voltage Linear analog voltage
Transfer function Temperature (°C) = (Voltage x 44.74364) -40.85555 °C
Temperature (°F) = (Voltage x 80.53855) -41.53999 °F
Temperature (°C) = (Voltage x 44.74364) - 40.85555 °C
Temperature (°F) = (Voltage x 80.53855) - 41.53999 °F

Note: Transfer function above applies to 4.6-meter cable. For sensors with cable lengths longer than 4.6 meters, subtract 0.002922 °C (0.0052596 °F) per additional meter from the transfer function offset.
Temperature (°C) = (Voltage x 44.74364) - 40.85555 °C
Temperature (°F) = (Voltage x 80.53855) - 41.53999 °F

Note: Transfer function above applies to 4.6-meter cable. For sensors with cable lengths longer than 4.6 meters, subtract 0.002922 °C (0.0052596 °F) per additional meter from the transfer function offset.
Temperature (°C) = (Voltage x 44.74364) - 40.85555 °C
Temperature (°F) = (Voltage x 80.53855) - 41.53999 °F

Note: Transfer function above applies to 4.6-meter cable. For sensors with cable lengths longer than 4.6 meters, subtract 0.002922 °C (0.0052596 °F) per additional meter from the transfer function offset.
Temperature (°C) = (Voltage x 44.74364) - 40.85555 °C
Temperature (°F) = (Voltage x 80.53855) - 41.53999 °F

Note: Transfer function above applies to 4.6-meter cable. For sensors with cable lengths longer than 4.6 meters, subtract 0.002922 °C (0.0052596 °F) per additional meter from the transfer function offset.
Please refer to your calibration report.
Accuracy Uncertainty (k=2): ±0.200 °C (±0.360 °F) Uncertainty (k=2): ±0.200 °C (±0.360 °F) Uncertainty (k=2): ±0.200 °C (±0.360 °F) Uncertainty (k=2): ±0.200 °C (±0.360 °F) Uncertainty (k=2): ±0.200 °C (±0.360 °F) Uncertainty (k=2): ±0.200 °C (±0.360 °F)
Output signal range 0.020 to 2.480 V DC 0.020 to 2.480 V DC 0.020 to 2.480 V DC 0.020 to 2.480 V DC 0.020 to 2.480 V DC 0.020 to 2.480 V DC
Turn on time <20 ms <20 ms <20 ms <20 ms <20 ms <20 ms
Resolution 0.0025 °C (0.0045 °F) 0.0025 °C (0.0045 °F) 0.0025 °C (0.0045 °F) 0.0025 °C (0.0045 °F) 0.0025 °C (0.0045 °F) 0.0025 °C (0.0045 °F)

RESPONSE CHARACTERISTICS

 
Thermal time constant 5.38 minutes 5.38 minutes 5.38 minutes 5.38 minutes 5.38 minutes 5.38 minutes

POWER REQUIREMENTS

 
Supply voltage 5 to 15 V DC

5 V pulsed excitation strongly recommended
5 to 15 V DC

5 V pulsed excitation strongly recommended
5 to 15 V DC

5 V pulsed excitation strongly recommended
5 to 15 V DC

5 V pulsed excitation strongly recommended
5 to 15 V DC

5 V pulsed excitation strongly recommended
5 to 15 V DC

5 V pulsed excitation strongly recommended
Supply current
  • 1.2 mA max. (no load on output)
  • SymphoniePRO Pulsed: 0.85 mA average
  • SymphoniePLUS3 Pulsed: 0.43 mA average
  • 1.2 mA max. (no load on output)
  • SymphoniePRO Pulsed: 0.85 mA average
  • SymphoniePLUS3 Pulsed: 0.43 mA average
  • 1.2 mA max. (no load on output)
  • SymphoniePRO Pulsed: 0.85 mA average
  • SymphoniePLUS3 Pulsed: 0.43 mA average
  • 1.2 mA max. (no load on output)
  • SymphoniePRO Pulsed: 0.85 mA average
  • SymphoniePLUS3 Pulsed: 0.43 mA average
  • 1.2 mA max. (no load on output)
  • SymphoniePRO Pulsed: 0.85 mA average
  • SymphoniePLUS3 Pulsed: 0.43 mA average
  • 1.2 mA max. (no load on output)
  • SymphoniePRO Pulsed: 0.85 mA average
  • SymphoniePLUS3 Pulsed: 0.43 mA average

INSTALLATION

 
Mounting Attaches to tower with included hose clamps Attaches to tower with included hose clamps Attaches to tower with included hose clamps Attaches to tower with included hose clamps Attaches to tower with included hose clamps Attaches to tower with included hose clamps
Tools required
  • 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
  • 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
  • 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
  • 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
  • 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
  • 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)

ENVIRONMENTAL

 
Operating temperature range -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F)
Operating humidity range 0 to 100% RH 0 to 100% RH 0 to 100% RH 0 to 100% RH 0 to 100% RH 0 to 100% RH
Lifespan 10 years + 10 years + 10 years + 10 years + 10 years + 10 years +
Other
  • IPX7 Rated
  • IPX7 Rated
  • IPX7 Rated
  • IPX7 Rated
  • IPX7 Rated
  • IPX7 Rated

PHYSICAL

 
Connections Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Cable length 4.6 m (15 ft) 13 m (42 ft) 67 m (220 ft) 90 m (295 ft) 110 m (361 ft) 13 m (42 ft)
Weight 0.47 kg (1.04 lbs) 0.75 kg (1.65 lbs) 2.53 kg (5.6 lbs) 3.29 kg (7.2 lbs) 3.94 kg (8.7 lbs) 0.75 kg (1.65 lbs)
Dimensions
  • Probe only: 51.6 mm (2") height x 12.7 mm (0.5") diameter
  • Radiation shield: 124 mm (4.9") height x 127 mm (5 inches) diameter
  • Probe only: 51.6 mm (2") height x 12.7 mm (0.5") diameter
  • Radiation shield: 124 mm (4.9") height x 127 mm (5 inches) diameter
  • Probe only: 51.6 mm (2") height x 12.7 mm (0.5") diameter
  • Radiation shield: 124 mm (4.9") height x 127 mm (5 inches) diameter
  • Probe only: 51.6 mm (2") height x 12.7 mm (0.5") diameter
  • Radiation shield: 124 mm (4.9") height x 127 mm (5 inches) diameter
  • Probe only: 51.6 mm (2") height x 12.7 mm (0.5") diameter
  • Radiation shield: 124 mm (4.9") height x 127 mm (5 inches) diameter
  • Probe only: 51.6 mm (2") height x 12.7 mm (0.5") diameter
  • Radiation shield: 124 mm (4.9") height x 127 mm (5 inches) diameter

MATERIALS

 
Cable 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket
Probe Aluminum, epoxy filled Aluminum, epoxy filled Aluminum, epoxy filled Aluminum, epoxy filled Aluminum, epoxy filled Aluminum, epoxy filled
Shield UV-stabilized thermoplastic solar radiation shield UV-stabilized thermoplastic solar radiation shield UV-stabilized thermoplastic solar radiation shield UV-stabilized thermoplastic solar radiation shield UV-stabilized thermoplastic solar radiation shield UV-stabilized thermoplastic solar radiation shield
  • Lower measurement uncertainty
  • ILAC-compliant, NIST-traceable calibrations available from an ISO 9001:2008, ISO/IEC 17025:2017 certified laboratory
  • Can measure up to 70°C (5°C greater than the 110S) 
  • Suitable for the temperature measurement requirements of remote wind and solar energy studies
  • Same physical design, body materials, and radiation shield as the 110S, ensuring seamless transition to T60

Related Products

product thumbnail

SRM System

Whether tracking or fixed, mono- or bifacial, 3 MW or 300 MW, NRG is focused on delivering repeatable solar resource measurements across your fleet of projects.

product thumbnail

SRA System

NRG Systems’ SRA System is a complete and integrated measurement solution for the prospecting and formal resource assessment of utility-scale photovoltaic projects.

product thumbnail

LOGR-S data logger

LOGR-S is NRG Systems’ first data logger designed specifically for the solar energy industry.

product thumbnail

NRG PVT1 PV temperature sensor

Because temperature has a significant impact on the performance of operational PV solar systems, PV module temperature is one of the most critical measurements to monitor and analyze.

product thumbnail

Li-Cor LI-200R pyranometer

The LI-200R measures Global Horizontal Irradiance (GHI) – the combination of Direct Normal Irradiance (DNI) and Diffuse horizontal irradiance (DHI).

product thumbnail

Hukseflux SR20 pyranometer

Recommended when measurement accuracy is the top priority, the Hukseflux SR20 is a thermopile pyranometer that is compliant with the highest category in the ISO 9060 standard: class A (Secondary Standard).

product thumbnail

EKO MS-40 pyranometer

The MS-40 Pyranometer is an ISO 9060-2018 Class C pyranometer that measures solar irradiance across the full Solar spectrum at a reasonable cost.

product thumbnail

EKO MS-60 pyranometer

The MS-60 Pyranometer is an ISO 9060-2018 Class B pyranometer with a millivolt analog output. The sensor features a double dome construction for lower offsets and cosine errors.

product thumbnail

EKO MS-80 pyranometer

The MS-80 Pyranometer is a unique pyranometer compliant to the “Fast response” and “Spectrally flat” sub-categories under ISO 9060:2018 Class A.

product thumbnail

Delta-T SPN1 sunshine pyranometer

The Delta-T SPN1 Sunshine Pyranometer measures global (total) and diffuse horizontal irradiance as well as sunshine duration.

product thumbnail

Hukseflux SR30-D1 pyranometer

The SR30 from Hukseflux provides class A (secondary standard) performance per ISO 9060:2018 along with a rich set of features that are unmatched by other sensors.

product thumbnail

EKO ms-80S pyranometer

The MS-80S Pyranometer is a unique pyranometer compliant to the “Fast response” and “Spectrally flat” sub-categories under ISO 9060:2018 Class A.

Unsolicited failed error
Please resend information

You have successfully submitted