Filter media test rig in accordance to DIN EN 1822-3 and ISO 29463-3 with U-SMPS for determination of MPPS range

MFP Nano Plus system

  • Particle size measurements from 10 nm
  • Internationally comparable measurement results in accordance with DIN EN 1822-3 and ISO 29463-3
  • Simple use of different test aerosols, such as NaCl / KCl or DEHS (others on request)
  • Easily movable dilution cascades with factors of 10, 100, 1,000 and 10,000 for measurements with salt or DEHS
  • Simple measurement of the fraction separation efficiency and determination of the MPPS range
  • High reproducibility of the testing method
  • Flexible filter test rig software FTControl
  • Easy to operate; even untrained personnel can be instructed quickly in the use of the equipment
  • Cleaning can be performed autonomously by the customer
  • Short set-up times
  • Mobile setup, easy to move on castors
  • Validation of the clear function of individual components and the overall system during pre-delivery acceptance testing and upon delivery
  • Reliable operation
  • Low-maintenance
  • Cut your operating costs with the MFP Nano Plus filter media inspection system

*Learn more about Palas: Here

*Fanpage: DIGI TECHNOLOGIES


Technical Data

Values
Measurement range (size) U-SMPS: 10 – 800 nm
Volume flow 0,48 – 5,76 m³/h (Pressurized Operation)
Power supply 115/230 V, 50/60 Hz
Dimensions Approx. 760 • 2100 • 985 mm (W • H • D)
Inflow velocity 1.3 – 16 cm/s (Other types on request)
Measurement of differential pressure
0 – 2500 Pa (Others on request)
Test area 100 cm²
Aerosols Dust (excample: SAE dust), salt (example: NaCl, KCl), liquid aerosol (eg DEHS)
Compressed air supply 6 – 8 bar
  • For filter media and small filter elements
  • Product development / production control
  • Test capabilities related to EN 1882-3 (HEPA/ULPA) and ISO 29463-3
  • Effective measurement of fractions in the range from approx. 20 nm to 1 µm

Related Products

product thumbnail

Dilution system – PMPD 1000

Dilution system ejector for the PMP application with dilution factor 1:1000. The PMPD 1000 dilution system is a dilution system according to the ejector principle that was especially developed for the PMP application or the PMP measurement chain. The PMPD 1000 achieves a dilution factor of 1:1000 by means of a thermodiluter up to 200°C.

product thumbnail

Dilution system – PMPD 100

Dilution system ejector for the PMP application with dilution factor 1:100 The PMPD 100 dilution system is a dilution system according to the ejector principle that was especially developed for the PMP application or the PMP measurement chain. The PMPD 100 achieves a dilution factor of 1:000 by means of a thermodiluter up to 200°C.

product thumbnail

Dilution systems – DC 10000

The DC 10000 consists of four cascaded special dilution systems with the dilution factor 1:10. The DC 10000 dilution cascade has one aerosol inlet and four aerosol outlets. Depending on which aerosol outlet is connected to the measuring device, the aerosol with the dilution factors 1:10, 1:100, 1:1,000 or 1:10,000 are diluted and measured.

product thumbnail

Dilution system – KHG 10

KHG 10 D dilution system heatable and pressure-resistant up to 10 bar for isothermal and isobaric dilution with a dilution factor of 1:10.

product thumbnail

Dilution system – VKL 100

Dilution system with dilution factor 1:100 The Palas® VKL 100 dilution systems are used in vertical operation for the particle size range up to 2 µm for applications in the clean room. Dilution factors of up to 1:100,000 are achieved by cascading several VKL systems.

product thumbnail

Dilution system – VKL 10

The VKL 10 series of dilution systems can reduce the concentration of aerosols by the dilution factor 01:10, also of very highly concentrated aerosols, in a defined and reliable way. The Palas® VKL 10 dilution systems are used in vertical operation for the particle size range up to 20 µm for powders and dusts. Dilution factors of up to 1:100,000 are achieved by cascading several VKL systems.

product thumbnail

Dilution system – LDD 100

The dilution of large droplets is particularly important when measuring highly concentrated droplet aerosols. Since large droplets are difficult to dilute, standard systems only work up to a size of 1 – 2 μm. The newly developed dilution system LDD 10 (dilution factor 10) is the first system to dilute almost loss-free large droplets up to 10 μm.

product thumbnail

Dilution system LDD 10

The dilution of large droplets is particularly important when measuring highly concentrated droplet aerosols. Since large droplets are difficult to dilute, standard systems only work up to a size of 1 – 2 μm. The newly developed dilution system LDD 10 (dilution factor 10) is the first system to dilute almost loss-free large droplets up to 10 μm.

product thumbnail

LSPG 16890 system

Aerosol generator for KCl and other salt particles up to 10 μm based on ISO 16890

product thumbnail

AGK 2000

Generation of solid particles out of suspensions, solutions and biological agents Solid particle aerosols produced from suspensions, e.g. with biological agents, and solutions such as NaCl and KCl, are required for numerous applications in research, development and quality assurance.

product thumbnail

DNP Digital 3000

Generation of nano-scale test aerosols from graphite, silver (Ag), gold (Au), copper (Cu), etc. through condensation; Carrier gas: Nitrogen or Argon (Replacement product of the GFG 1000)

product thumbnail

BEG 3000

Test aerosols from powder, dust, pollen, etc.; mass flow approx. 8 g/h – 7.3 kg/h; with automatic mass flow monitoring and refill unit