MFP 4000 system

Product code:MFP 4000
Supplier:Palas
Price: Inquiry
Description
Specifications
Application
Download

MFP 4000 with two Promo® aerosol spectrometers for simultaneous determination of fraction separation efficiency

MFP 4000 system

  • Simultaneous particle measurement in the raw gas and clean gas
  • Particle size measurements from 0.2 – 40 µm
  • Measurement of Cn max= 10^6 particles/cm3 without dilution
  • Internationally comparable measurement results
  • Widespread distribution of the measurement system
  • High reproducibility of the testing method
  • Easy use of different test aerosols, e.g. SAE Fine and Coarse, NaCl/KCl, DEHS
  • Highest raw gas concentrations of up to > 1000 mg/m3 (ISO Fine) or > 5000 mg/m3 (ISO Coarse) with measurement of the fraction separation efficiency for burden tests
  • Flexible filter test rig software FTControl
  • Sequence programs for pressure loss measurements, measurements of fraction separation efficiency and burden measurements
  • Easy to operate, even untrained personnel can be instructed quickly in the use of the equipment
  • MFP 4000 filter media inspection system with short installation time
  • Cleaning and calibration can be performed autonomously by the customer
  • Easy use of the measurement technology components – even in other applications
  • Mobile setup, easy to move on castors

*Learn more about Palas: Here

*Fanpage: DIGI TECHNOLOGIES

Measurement range (size) 0.2 – 40 µm
Measurement range (mass) Up to 1,000 mg/m³ (depending on the version)
Volume flow 1 – 35 m3/h - suction mode
Inflow velocity 5 – 100 cm/s (others on request)
Differential pressure measurement 0 – 1,200 Pa selectable, 0 – 2,500 Pa selectable, 0 – 5,000 Pa selectable
Aerosols Dusts (e.g., SAE dusts), salts (e.g., NaCl, KCl), liquid aerosols (e.g., DEHS)
Compressed air supply 6 – 8 bar
Test area of the medium 100 cm2
  • For filter media and small filter elements
  • product development/ during production monitoring.
  • Testing based on ISO 11155-1 / DIN 71460-1 (cabin air filters), Testing based on ISO 5011 (engine pre-air filters), Testing based on ISO 16890 (room air filters), Other standards in various versions.

Related Products

product thumbnail

Dilution system – PMPD 1000

Dilution system ejector for the PMP application with dilution factor 1:1000. The PMPD 1000 dilution system is a dilution system according to the ejector principle that was especially developed for the PMP application or the PMP measurement chain. The PMPD 1000 achieves a dilution factor of 1:1000 by means of a thermodiluter up to 200°C.

product thumbnail

Dilution system – PMPD 100

Dilution system ejector for the PMP application with dilution factor 1:100 The PMPD 100 dilution system is a dilution system according to the ejector principle that was especially developed for the PMP application or the PMP measurement chain. The PMPD 100 achieves a dilution factor of 1:000 by means of a thermodiluter up to 200°C.

product thumbnail

Dilution systems – DC 10000

The DC 10000 consists of four cascaded special dilution systems with the dilution factor 1:10. The DC 10000 dilution cascade has one aerosol inlet and four aerosol outlets. Depending on which aerosol outlet is connected to the measuring device, the aerosol with the dilution factors 1:10, 1:100, 1:1,000 or 1:10,000 are diluted and measured.

product thumbnail

Dilution system – KHG 10

KHG 10 D dilution system heatable and pressure-resistant up to 10 bar for isothermal and isobaric dilution with a dilution factor of 1:10.

product thumbnail

Dilution system – VKL 100

Dilution system with dilution factor 1:100 The Palas® VKL 100 dilution systems are used in vertical operation for the particle size range up to 2 µm for applications in the clean room. Dilution factors of up to 1:100,000 are achieved by cascading several VKL systems.

product thumbnail

Dilution system – VKL 10

The VKL 10 series of dilution systems can reduce the concentration of aerosols by the dilution factor 01:10, also of very highly concentrated aerosols, in a defined and reliable way. The Palas® VKL 10 dilution systems are used in vertical operation for the particle size range up to 20 µm for powders and dusts. Dilution factors of up to 1:100,000 are achieved by cascading several VKL systems.

product thumbnail

Dilution system – LDD 100

The dilution of large droplets is particularly important when measuring highly concentrated droplet aerosols. Since large droplets are difficult to dilute, standard systems only work up to a size of 1 – 2 μm. The newly developed dilution system LDD 10 (dilution factor 10) is the first system to dilute almost loss-free large droplets up to 10 μm.

product thumbnail

Dilution system LDD 10

The dilution of large droplets is particularly important when measuring highly concentrated droplet aerosols. Since large droplets are difficult to dilute, standard systems only work up to a size of 1 – 2 μm. The newly developed dilution system LDD 10 (dilution factor 10) is the first system to dilute almost loss-free large droplets up to 10 μm.

product thumbnail

LSPG 16890 system

Aerosol generator for KCl and other salt particles up to 10 μm based on ISO 16890

product thumbnail

AGK 2000

Generation of solid particles out of suspensions, solutions and biological agents Solid particle aerosols produced from suspensions, e.g. with biological agents, and solutions such as NaCl and KCl, are required for numerous applications in research, development and quality assurance.

product thumbnail

DNP Digital 3000

Generation of nano-scale test aerosols from graphite, silver (Ag), gold (Au), copper (Cu), etc. through condensation; Carrier gas: Nitrogen or Argon (Replacement product of the GFG 1000)

product thumbnail

BEG 3000

Test aerosols from powder, dust, pollen, etc.; mass flow approx. 8 g/h – 7.3 kg/h; with automatic mass flow monitoring and refill unit