CIF 3000 system

Product code:CIF 3000
Supplier:Palas
Price: Inquiry
Description
Specifications
Application
Download

CIF 3000 test rig for standard tests on motor vehicle passenger compartment filters in accordance with DIN 71460 part 1 and ISO/TS 11155-1

CIF 3000 system:

  • Particle measurements from 200 nm
  • Virtually simultaneous raw gas and clean gas measurement
  • Automatic data acquisition for barometer pressure, temperature, humidity, differential pressure
  • Temperature control (+18°C to +90°C) and moisture control (30 – 70%)
  • Automatic actuation of all test rig components
  • Automatic performance of the measurement processes
  • Individual programming of measurement processes for filter testing using the FTControl software
  • Separate measurement and analysis parts – this saves time and money, as the analysis can be performed while the measurement is still on-going
  • Printouts and saving of complete test records
  • Easy access to all data for the recorded measurement signals from the up to 6 external sensors
  • Low-maintenance
  • Easy operation and Reliable operation
  • Save on operating costs with the 3000 CIF filter test system

 

*Learn more about Palas: Here

*Fanpage: DIGI TECHNOLOGIES


Technical Data

Description
Measurement range (size) 0.2 – 40 µm
Volume flow 60 m3/h – 800 m3/h (cycle operation)
Dimensions Test rig: 1,000 • 2,800 • 4,200 mm

Filter holder: 300 • 600 mm (filter and others on request)

Material Stainless steel V2A, 2 mm
Temperature regulation +18 °C – +90 °C
Luftfeuchteregelung 30% up to 70%
Temperature- and humidity sensor Measuring range: -20°C - +80°C, 0 - 100 % rH,

Accuracy: ± 0.1°C (20°C), ± 1 % rH (0 - 90 % rH), ± 2 % rH (90 - 100 % rH)

Barometric pressure gauge Measuring range: 600 - 1100 hPa,

Accuracy: ± 0.10 hPa

Differential pressure gauge Measuring range: < 2500

PaLinearity error: < 0.2 % of final value

Measurement of the air velocity Measuring range: 0.5 – 40 m/s,

Accuracy: < +/- 0.05 m/s (up to 20 m/s), < +/- 0.08 m/s (20 – 30 m/s), < +/- 0.1 m/s (30 – 40 m/s)

Preconditions 3 phases, 400 V, neutral, earth connection of approx. 3 KW and provision of pressurized air max. 8 bar
  • Complete filter test in accordance with DIN 71460 part 1 & ISO/TS 11155 part 1
  • Test of filter media in accordance with DIN 71460 part 1 & ISO/TS 11155 part 1
  • Testing of other complete filters and filter media

Related Products

product thumbnail

Dilution system – PMPD 1000

Dilution system ejector for the PMP application with dilution factor 1:1000. The PMPD 1000 dilution system is a dilution system according to the ejector principle that was especially developed for the PMP application or the PMP measurement chain. The PMPD 1000 achieves a dilution factor of 1:1000 by means of a thermodiluter up to 200°C.

product thumbnail

Dilution system – PMPD 100

Dilution system ejector for the PMP application with dilution factor 1:100 The PMPD 100 dilution system is a dilution system according to the ejector principle that was especially developed for the PMP application or the PMP measurement chain. The PMPD 100 achieves a dilution factor of 1:000 by means of a thermodiluter up to 200°C.

product thumbnail

Dilution systems – DC 10000

The DC 10000 consists of four cascaded special dilution systems with the dilution factor 1:10. The DC 10000 dilution cascade has one aerosol inlet and four aerosol outlets. Depending on which aerosol outlet is connected to the measuring device, the aerosol with the dilution factors 1:10, 1:100, 1:1,000 or 1:10,000 are diluted and measured.

product thumbnail

Dilution system – KHG 10

KHG 10 D dilution system heatable and pressure-resistant up to 10 bar for isothermal and isobaric dilution with a dilution factor of 1:10.

product thumbnail

Dilution system – VKL 100

Dilution system with dilution factor 1:100 The Palas® VKL 100 dilution systems are used in vertical operation for the particle size range up to 2 µm for applications in the clean room. Dilution factors of up to 1:100,000 are achieved by cascading several VKL systems.

product thumbnail

Dilution system – VKL 10

The VKL 10 series of dilution systems can reduce the concentration of aerosols by the dilution factor 01:10, also of very highly concentrated aerosols, in a defined and reliable way. The Palas® VKL 10 dilution systems are used in vertical operation for the particle size range up to 20 µm for powders and dusts. Dilution factors of up to 1:100,000 are achieved by cascading several VKL systems.

product thumbnail

Dilution system – LDD 100

The dilution of large droplets is particularly important when measuring highly concentrated droplet aerosols. Since large droplets are difficult to dilute, standard systems only work up to a size of 1 – 2 μm. The newly developed dilution system LDD 10 (dilution factor 10) is the first system to dilute almost loss-free large droplets up to 10 μm.

product thumbnail

Dilution system LDD 10

The dilution of large droplets is particularly important when measuring highly concentrated droplet aerosols. Since large droplets are difficult to dilute, standard systems only work up to a size of 1 – 2 μm. The newly developed dilution system LDD 10 (dilution factor 10) is the first system to dilute almost loss-free large droplets up to 10 μm.

product thumbnail

LSPG 16890 system

Aerosol generator for KCl and other salt particles up to 10 μm based on ISO 16890

product thumbnail

AGK 2000

Generation of solid particles out of suspensions, solutions and biological agents Solid particle aerosols produced from suspensions, e.g. with biological agents, and solutions such as NaCl and KCl, are required for numerous applications in research, development and quality assurance.

product thumbnail

DNP Digital 3000

Generation of nano-scale test aerosols from graphite, silver (Ag), gold (Au), copper (Cu), etc. through condensation; Carrier gas: Nitrogen or Argon (Replacement product of the GFG 1000)

product thumbnail

BEG 3000

Test aerosols from powder, dust, pollen, etc.; mass flow approx. 8 g/h – 7.3 kg/h; with automatic mass flow monitoring and refill unit

Unsolicited failed error
Please resend information

You have successfully submitted