The 40C was one of the first anemometers designed exclusively for the wind industry.

 

The 40C Anemometer has recorded wind speeds of 96 m/s (214 mph). Their bearings and low moment of inertia permit very rapid response to gusts and lulls. Due to their output linearity, these sensors are ideal for use with various data retrieval systems. A four-pole magnet induces a sine wave voltage into a coil, producing an output signal with frequency proportional to wind speed.

 

Constructed of rugged Lexan cups, the 40C is molded in one piece for repeatable performance. A rubber terminal boot is included with each anemometer for additional protection from the elements.

 

A MEASNET calibration certificate is available for each sensor

 
MEASNET Calibrated (#1900)

CPH MEASNET Calibrated (#4350)

DESCRIPTION

 
Sensor type 3 Cup Anemometer 3 Cup Anemometer
Applications
  • Wind resource assessment
  • Meteorological studies
  • Environmental monitoring
  • Wind resource assessment
  • Meteorological studies
  • Environmental monitoring
Sensor range 1 m/s to 96 m/s (2.2 mph to 215 mph) (highest recorded) 1 m/s to 96 m/s (2.2 mph to 215 mph) (highest recorded)
Instrument compatibility All NRG loggers All NRG loggers

OUTPUT SIGNAL

 
Signal type Low level AC sine wave, frequency linearly proportional to wind speed Low level AC sine wave, frequency linearly proportional to wind speed
Anemometer Transfer Function
  • Consensus Transfer Function:
    Scale Factor (Slope): 0.765 m/s/Hz (1.711 mph/Hz)
    Offset: 0.35 m/s (0.78 mph)
  • Refer to the white paper "The Maximum Type 40 Anemometer Calibration Project" for more information on the consensus transfer function
  • All NRG 40C Anemometers are calibrated per IEC 61400-12-1, Annex F
See individual calibration report
Output voltage at threshold 80 mV (peak-to-peak) minimum 80 mV (peak-to-peak) minimum
Output voltage at 60Hz
  • 12 V (peak-to-peak) typical
  • Output amplitude NOT proportional to wind speed
  • 12 V (peak-to-peak) typical
  • Output amplitude NOT proportional to wind speed
Calibration Each anemometer individually calibrated, calibration reports provided via electronic download Each anemometer individually calibrated, calibration reports provided via electronic download
Output signal range 0 Hz to 125 Hz (at 96m/s, highest recorded) 0 Hz to 125 Hz (at 96m/s, highest recorded)
Uncertainty Accuwind (Riso-R-1556) Classification:
  • Class 2.4A
  • Class 7.7B
    IEC 61400-12-1 operational standard uncertainty:
  • ± 0.14 m/s at 10 m/s for Class A
  • ± 0.45 m/s at 10 m/s for Class B
  • Refer to calibration sheet for information on calibration uncertainty
  • Refer to application note "#40C Anemometer Uncertainty" for definitions and more information
Accuwind (Riso-R-1556) Classification:
  • Class 2.4A
  • Class 7.7B
    IEC 61400-12-1 operational standard uncertainty:
  • ± 0.14 m/s at 10 m/s for Class A
  • ± 0.45 m/s at 10 m/s for Class B
  • Refer to calibration sheet for information on calibration uncertainty
  • Refer to application note "#40C Anemometer Uncertainty" for definitions and more information

RESPONSE CHARACTERISTICS

 
Distance constant (63% recovery)
  • 2.55 m (8.37 feet) at 5m/s per ASTM D 5096-02
  • 2.56 m (8.40 feet) at 10m/s per ASTM D 5096-02
  • 2.55 m (8.37 feet) at 5m/s per ASTM D 5096-02
  • 2.56 m (8.40 feet) at 10m/s per ASTM D 5096-02
Moment of inertia
  • 1.01 x 10-4 kg-m2
  • 74.5 x 10-6 S-ft2
  • 1.01 x 10-4 kg-m2
  • 74.5 x 10-6 S-ft2
Swept diameter of rotor 190 mm (7.5 inches) 190 mm (7.5 inches)

INSTALLATION

 
Mounting Onto a 13 mm (0.5") diameter mast with cotter pin and set screw Onto a 13 mm (0.5") diameter mast with cotter pin and set screw
Tools required 0.25 inch nut driver, petroleum jelly, electrical tape 0.25 inch nut driver, petroleum jelly, electrical tape

ENVIRONMENTAL

 
Operating temperature range -55 °C to 60 °C (-67 °F to 140 °F) -55 °C to 60 °C (-67 °F to 140 °F)
Operating humidity range 0 to 100% RH 0 to 100% RH

PHYSICAL

 
Connections 4-40 brass hex nut/post terminals 4-40 brass hex nut/post terminals
Weight 0.14 kg (0.3 lbs) 0.14 kg (0.3 lbs)
Dimensions
  • 3 cups of conical cross-section, 51 mm (2") dia.
  • 81 mm (3.2") overall assembly height
  • 3 cups of conical cross-section, 51 mm (2") dia.
  • 81 mm (3.2") overall assembly height

MATERIALS

 
Cups One piece injection-molded black polycarbonate One piece injection-molded black polycarbonate
Body Housing is black ABS plastic Housing is black ABS plastic
Shaft Beryllium copper, fully hardened Beryllium copper, fully hardened
Bearing Modified Teflon, self-lubricating Modified Teflon, self-lubricating
Magnet Indox 1, 25 mm (1 inch) diameter, 13 mm (0.5 inch) long, 4 poles Indox 1, 25 mm (1 inch) diameter, 13 mm (0.5 inch) long, 4 poles
Coil Single coil, bobbin wound, 4100 turns of #40 wire, shielded for ESD protection Single coil, bobbin wound, 4100 turns of #40 wire, shielded for ESD protection
Boot Protective PVC sensor terminal boot included Protective PVC sensor terminal boot included
Terminals Brass Brass

Related Products

product thumbnail

SRM System

Whether tracking or fixed, mono- or bifacial, 3 MW or 300 MW, NRG is focused on delivering repeatable solar resource measurements across your fleet of projects.

product thumbnail

SRA System

NRG Systems’ SRA System is a complete and integrated measurement solution for the prospecting and formal resource assessment of utility-scale photovoltaic projects.

product thumbnail

LOGR-S data logger

LOGR-S is NRG Systems’ first data logger designed specifically for the solar energy industry.

product thumbnail

NRG PVT1 PV temperature sensor

Because temperature has a significant impact on the performance of operational PV solar systems, PV module temperature is one of the most critical measurements to monitor and analyze.

product thumbnail

Li-Cor LI-200R pyranometer

The LI-200R measures Global Horizontal Irradiance (GHI) – the combination of Direct Normal Irradiance (DNI) and Diffuse horizontal irradiance (DHI).

product thumbnail

Hukseflux SR20 pyranometer

Recommended when measurement accuracy is the top priority, the Hukseflux SR20 is a thermopile pyranometer that is compliant with the highest category in the ISO 9060 standard: class A (Secondary Standard).

product thumbnail

EKO MS-40 pyranometer

The MS-40 Pyranometer is an ISO 9060-2018 Class C pyranometer that measures solar irradiance across the full Solar spectrum at a reasonable cost.

product thumbnail

EKO MS-60 pyranometer

The MS-60 Pyranometer is an ISO 9060-2018 Class B pyranometer with a millivolt analog output. The sensor features a double dome construction for lower offsets and cosine errors.

product thumbnail

EKO MS-80 pyranometer

The MS-80 Pyranometer is a unique pyranometer compliant to the “Fast response” and “Spectrally flat” sub-categories under ISO 9060:2018 Class A.

product thumbnail

Delta-T SPN1 sunshine pyranometer

The Delta-T SPN1 Sunshine Pyranometer measures global (total) and diffuse horizontal irradiance as well as sunshine duration.

product thumbnail

Hukseflux SR30-D1 pyranometer

The SR30 from Hukseflux provides class A (secondary standard) performance per ISO 9060:2018 along with a rich set of features that are unmatched by other sensors.

product thumbnail

EKO ms-80S pyranometer

The MS-80S Pyranometer is a unique pyranometer compliant to the “Fast response” and “Spectrally flat” sub-categories under ISO 9060:2018 Class A.

Unsolicited failed error
Please resend information

You have successfully submitted